Send Message
Suzhou Beite Smart Instrument Co., Ltd
Email sale@beitemeter.com TEL: 86-400-839-1983
Home > products > Flow Meter >
Precession Vortex Flowmeter High Flow Range And Accuracy Level For Gas Measurement
  • Precession Vortex Flowmeter High Flow Range And Accuracy Level For Gas Measurement
  • Precession Vortex Flowmeter High Flow Range And Accuracy Level For Gas Measurement

Precession Vortex Flowmeter High Flow Range And Accuracy Level For Gas Measurement

Place of Origin CHINA
Brand Name BEITE
Certification CE ISO
Product Details
Highlight: 

high Precession Vortex Flowmeter

,

Gas Measurement Precession Vortex Flowmeter

,

high Accuracy Level Precession Vortex Flowmeter

Payment & Shipping Terms
Minimum Order Quantity
1 Piece/Pieces
Price
Negotiate
Packaging Details
carton or customers requests available
Delivery Time
5 working days after payment
Payment Terms
T/T, Western Union
Supply Ability
3000 Piece/Pieces per Month mini flow meter
Product Description

The technical parameters of vortex gas flowmeters can vary according to different brands and models, but generally speaking, the technical parameters of vortex gas flowmeters include the following important indicators:

1. **Flow range** (flow range)

- **Measurement range**: Flowmeters usually have a wide measurement range, generally ranging from a few cubic meters per hour (m³/h) to several thousand cubic meters per hour (m³/h). The specific range depends on the model and design of the flowmeter.

- **Minimum flow (lower flow limit)**: The minimum flow value that the flowmeter can accurately measure is usually marked.

- **Maximum flow**: The maximum flow value exceeding this value may affect the accuracy of the flowmeter or cause damage.

2. **Accuracy level**

- The accuracy of vortex gas flowmeters is generally **±1%~±2%** (percentage of the range value), and high-end products can reach **±0.5%** or higher.

- Accuracy is usually related to the flow range, stability of the medium, properties of the fluid, etc.

3. **Working medium**
- **Gas type**: Swirl gas flowmeters are suitable for measuring a variety of gas flows, such as natural gas, compressed air, nitrogen, oxygen, steam, fuel gas, etc.
- **Gas density and composition**: Flowmeters usually require the measurement of gas density and composition, and some high-precision models can automatically compensate for changes in gas density.

4. **Working pressure**
- The working pressure range of swirl gas flowmeters is usually **0.1 MPa ~ 10 MPa** or higher, depending on the specifications of the flowmeter. Some high-pressure versions can be used for applications under higher pressures.

5. **Working temperature**
- **Normal working temperature**: Generally between **-40°C ~ 120°C**.
- **High or low temperature type**: Some special models support higher or lower working temperature ranges, suitable for industrial high-temperature and low-temperature gas flow measurement.

6. **Material and corrosion resistance**
- The main material of the flowmeter is usually **stainless steel** (such as 304, 316), and corrosion-resistant coating or special alloy materials can be selected according to needs, which is suitable for measuring corrosive gases.
- Some models also provide **explosion-proof** certification to adapt to the measurement environment of hazardous gases.

7. **Output signal**
- **Pulse signal output**: The vortex gas flowmeter usually outputs flow data through a pulse signal, and the pulse frequency is proportional to the flow rate.
- **Analog signal output**: Some flowmeters provide analog output (such as 4-20 mA, 0-10V, etc.) to connect with the flow control system or data acquisition system.
- **Digital signal output**: Some models support digital communication protocols such as **Modbus, HART**, etc., which is convenient for remote monitoring and data acquisition.

8. **Installation method**
- Flowmeters usually have two designs: **pipe installation type** and **insertion type**, which can be selected according to the size of the pipeline and the application scenario.
- The installation location of the device will also affect the measurement accuracy, usually requiring smooth fluid flow and sufficient straight pipe length.

9. **Overload capacity**
- Most flow meters have a certain overload capacity, such as **1.5 to 2 times the range**, to cope with short-term flow fluctuations or shocks.

10. **Response time**
- The response time is generally **0.5 seconds to 3 seconds**, depending on the design of the flow meter and the characteristics of the fluid. A faster response time helps to monitor gas flow changes in real time.

11. **Display and data acquisition**
- Some swirl gas flow meters are equipped with **local display** (LCD or LED) to display flow values ​​in real time.
- Optional **temperature and pressure compensation** functions can further improve measurement accuracy.

12. **Protection level**
- The protection level is usually **IP65, IP67**, which is dustproof and waterproof, and can be used outdoors or in harsh environments.

13. **Power Requirements**
- The power requirements for vortex gas flowmeters are usually **DC 24V** or **AC 220V**, but some models may support a wider power voltage range.

14. **Explosion-proof Certification**
- When used in an explosive gas environment, the flowmeter may require **Ex explosion-proof certification** to ensure the safe operation of the device in hazardous environments.
Summary:
The specific technical parameters of the vortex gas flowmeter depend on the device model and its design requirements. When selecting a model, you need to consider factors such as the working environment, flow range, gas type, and accuracy requirements.

Description
 

LUXZ series intelligent precession vortex flowmeter is a new type of gas flow meter developed by our company. This flowmeter integrates flow, temperature, and pressure detection functions, and can automatically compensate for temperature, pressure, and compression factors. It is an ideal instrument for gas measurement in petroleum, chemical, electric power, metallurgy, and other industries.

 

The intelligent flow meter integrates a flow probe, microprocessor, pressure, and temperature sensors into one. It adopts a built-in combination to make the structure more compact. It can directly measure the flow rate, pressure and temperature of the fluid, and automatically track compensation and compression factor correction in real time;
The LUXZ series intelligent precession vortex flowmeter can be widely used in petroleum, chemical industry, electric power, metallurgy, urban gas supply and other industries to measure various gas flows. It is currently a commonly used product in oil fields and urban natural gas transmission and distribution measurement and trade measurement.


Specification

 

No mechanical moving parts, not easy to corrode, stable and reliable, long life, no special maintenance required for long-term operation;

Using 16-bit computer chip, it has high integration, small size, good performance and strong overall function;

 

The intelligent flow meter integrates a flow probe, microprocessor, pressure, and temperature sensors into one. It adopts a built-in combination to make the structure more compact. It can directly measure the flow rate, pressure and temperature of the fluid, and automatically track compensation and compression factor correction in real time;

 

The use of dual detection technology can effectively improve the detection signal strength and suppress interference caused by pipeline vibration;

Using intelligent anti-seismic technology, it effectively suppresses interference signals caused by vibration and pressure fluctuations;

It adopts a Chinese character dot matrix display with many display digits and intuitive and convenient readings. It can directly display the volume flow rate under working conditions, the volume flow rate under standard conditions, the total amount, as well as medium pressure, temperature and other parameters;

 

Adopting EEPROM technology, the parameters are easy to set and can be saved, and historical data for up to one year can be saved;

The converter can output frequency pulses, 4~20mA analog signals, and has an RS485 interface, which can be directly connected to the computer network, and the transmission distance can reach 1.2km;

 

Multiple physical parameters alarm output, one of which can be selected by the user;

 

The flow meter head can be rotated 360 degrees, making installation and use simple and convenient;

 

With the company's FM data collector, remote data transmission can be carried out through the Internet or telephone network

The pressure and temperature signals are input by sensors and are highly interchangeable;

 

The whole machine has low power consumption and can be powered by internal battery or external power supply.

model code tips
BTLUXZ ……………………………………………… Precession vortex flowmeter
Explosion-proof type -B……………………………………… Explosionproof type
Transmitter type A……………………………………B…………………………………… Round LCD display
Square LCD display
Signal output M…………………………… pulse
L…………………………… 4~20mA current
R…………………………… RS485 communication interface
MR…………… ………… Equivalent pulse RS485 also has
Nominal pressure -016 ……………… 1.6MPa
-025 ……………… 2.5MPa
-040………………… 4.0Mpa
-063………………… 6.3Mpa
Nominal diameter -015……………… 15mm
-020……………… 20mm
-025……………… 25mm
-032……………… 32mm
-040……………… 40mm
-050……………… 50mm
-080……………… 80mm
-100……………… 100mm
-150……………… 150mm
-200……………… 200mm
Accuracy A Level 1.5
B Level 1.0

 

Features

 

Smart design
1. METAL STRUCTURE DESIGN
Core technology is developed and manufactured with stable system performance.
easy to use
2.  CASE STRUCTURE DESIGN
The new shell structure design is simple and convenient to operate, and can be used in high temperature environments without adding additional parts.
Flexible and controllable
3. CONICAL MEASURING TUBE
The measurement data is accurate, the measurement range is wider, and the measurement linearity is better.
Various connection methods
4. CONNECTION METHODS
A variety of process connection methods such as flanges, clamps, and threads are available to suit most factory application needs.
Measurement of some materials optional
5. MATERIAL OPTIONAL
Stainless steel, titanium, Hastelloy, PTFE, FEP and other materials.
Combined installation
6. MAGNETIC COUPLING SYSTEM
The flow meter head can be rotated 360 degrees, which is simple and convenient to install and use.

 

Packing & Delivery
Insertion type thermal gas mass flow meter RS-485,Modbus,RTU 1

FAQ
1. Q: What information need to be provided to choose the suitable model?
A: Application field, Nominal pressure ,Medium & medium temperture , Power supply , Output,
Flow range, Accuracy, Connection and other parameters.
2. Q: Are you a trade company or a manufacturer?
A: We are an ISO approved manufacturer specialized in level and flow measuring instruments.
OEM & ODM service are available. Welcome to visit us in China.
3. Q: What is your MOQ?
A: To start our cooperation, sample order is acceptable.
4. Q: What is your delivery date for the Intelligent Mini Micro Turbine Fuel Oil Diesel Flow Meter?
A: The delivery date is about 3-15 working days after receipt of payment.
5. Q: What is your payment terms?
A: We support T/T, PayPal ,Western Union.
For mass production order, it is 30% deposit in advance and 70% balance before shipment.
6. Q: Do you have a warranty for the Flow Meter?
A: Yes, we have the warranty of 12 months.

 

Contact Us at Any Time

86-400-839-1983
No. 66, Changwang Road, Dongqiao Town, Xiangcheng District, Suzhou City, Jiangsu Province
Send your inquiry directly to us