Send Message
Suzhou Beite Smart Instrument Co., Ltd
Email sale@beitemeter.com TEL: 86-400-839-1983
Home > products > Pressure Instrument >
Differential Pressure Transmitter With Anti-Corrosion Materials For Harsh Environments
  • Differential Pressure Transmitter With Anti-Corrosion Materials For Harsh Environments
  • Differential Pressure Transmitter With Anti-Corrosion Materials For Harsh Environments
  • Differential Pressure Transmitter With Anti-Corrosion Materials For Harsh Environments

Differential Pressure Transmitter With Anti-Corrosion Materials For Harsh Environments

Place of Origin CHINA
Brand Name BEITE
Certification CE ISO
Model Number RP62 Series
Product Details
Ambient Temperature:
-40~85℃
Body Temperature:
Diffused Silicon Pressure Transmitter
Communication Protocol:
HART
Mounting Type:
DIN Rail Or Wall Mount
Relative Humidity:
5~98%RH
Customization:
Available OEM And ODM
Dia:
100mm
Thread:
G1/4,custom
Compensated Temperatures:
-10~+60℃
Highlight: 

Harsh Environments Pressure Transmitter

,

Harsh Environments Differential Pressure Transmitter

,

Anti-Corrosion Materials Differential Pressure Transmitter

Payment & Shipping Terms
Minimum Order Quantity
1 Piece/Pieces
Price
Negotiate
Packaging Details
carton or customers requests available
Delivery Time
5 working days after payment
Payment Terms
T/T, Western Union
Supply Ability
3000 Piece/Pieces per Month mini flow meter
Product Description

 

Description

 

RP62 is equipped with a microprocessor that can measure a variety of pressures, supports multiple outputs and multiple parameter settings, and can implement HART ® communication functions and other operations. According to the usage method, pressure measurement, flow measurement and liquid level measurement can be performed.

 

Differential Pressure Transmitter With Anti-Corrosion Materials For Harsh Environments 0


Specification

 

Process interface materials Process Isolation Diaphragm: 316L SS, Hastelloy C-276, Monel, Tantalum
Process interface: 316SS, carbon steel (galvanized), Hastelloy, Monel
O-ring gasket: Teflon, fluorinated rubber
Exhaust/drain valve: 316L SS, Hastelloy C-276
Bolt: Carbon Steel, A286 SS (NACE)
Note: There are other special anti-corrosion materials available for the wetted parts, which can be used under various working conditions. Please contact VIRVO ® Company
Mounting brackets Carbon steel (galvanized) or stainless steel angle brackets, carbon steel flat brackets
filling fluid Silicone oil DC200 or CTFE (fluorine oil)
watch case Epoxy polyester paint, low copper aluminum alloy. Meets NEMA 4X (waterproof) and NEMA 7 (explosion-proof) requirements, available in stainless steel
process connection 1/4NPT, 1/2NPT conversion joint (optional)
Wiring 16AWG (1.5mm diameter)
net weight 4.2kg, about 5kg including accessories
Package Size 234X185X155mm
Nameplate 304 stainless steel
Hazardous area certification With explosion-proof and intrinsically safe certification, it can be used in Class I, Devision 1, Group A, B, C, D situations, and non-flammable Class I.
Devision 2, GroupA, B, C, D occasions. ATEX standard EEx ia ⅡCT4, T5, T6 and EExd ⅡCT5, T6 certification

 

 

Electrical indicators

 

voltage 11.9~45 VDC output signal 4~20mA DC/HART
HART load resistor 250~1500Ω Insulation voltage 500 Vrms (707VDC)
Damping time 0.25S Start Time 5S

 

 

Performance

 

Accuracy ±0.075% of span
(0.2URL≤Span≤URL)
±[0.05+0.005x(URL/Span)]%
of Span(0.05URL≤Span<0.2URL)
Stability ±0.01% full scale/year
Temperature effect ±[0.025%URL+0.125% Span]/28
Vibration effect The frequency on any axis is 200Hz, and the error caused is ±0.05%/g of the measuring range.
Power supply voltage effect 0.005% full scale/volt
CE certification 89/336/EEC, electromagnetic compatibility (EMC) standard

 

 

Operating environment

 

parameter Rated environment operating limits transportation and storage
Ambient temperature (℃) -40~85 -40~91 -55~125
Surface temperature (℃) -40~110 -40~125 -55~125
Humidity (%RH) 10~85 0~100 0~100
Overvoltage capability 14MPa, special up to 21MPa
Vacuum degree (KPa) 0 3.5 --

 

 

product structure

Differential Pressure Transmitter With Anti-Corrosion Materials For Harsh Environments 1

Differential Pressure Transmitter With Anti-Corrosion Materials For Harsh Environments 2

Differential Pressure Transmitter With Anti-Corrosion Materials For Harsh Environments 3

Differential Pressure Transmitter With Anti-Corrosion Materials For Harsh Environments 4

Precautions

 

The use of a transmitter side exhaust / drain valve, taps should be installed to the side
flow pipeline. Working medium for the level, exhaust gas / liquid discharging valve arranged
on the flange of the upper to exhaust gas; working medium for the gas, vent / drain valve
installed in the lower flange to discharge liquid; flange rotation of 180 DEG, side exhaust /
drain valve from the upper to the lower.
Note: The measurement of steam or other high temperature media, medium
temperature can not contact with the transmitter over its use for temperature limit.
When measuring steam, the pressure inside the tube must be filled with water, to
prevent direct contact with steam and transmitter. Because the volume change quantity
transmitter is very small, so it does not require the condenser.
Pipeline pressure port connecting the transmitter and the measured media is a
transmission channel pressure, the pressure transfer process, factors may introduce error
include
1) Loss of pressure
2) The friction loss of pressure pipe
3) The accumulated gas of pipeline in the liquid medium
4) The accumulated liquid of pipeline in the gas medium
Differential Pressure Transmitter With Anti-Corrosion Materials For Harsh Environments 5
Installation with mounting bracket
 
2 inch pipe vertical bracket
Differential Pressure Transmitter With Anti-Corrosion Materials For Harsh Environments 6

 

Features

 

/MULTIPLE INPUTS
Differential pressure type (DP), gauge pressure type (GP), absolute pressure (AP)

/MULTIPLE OUTPUTS
4 ~20mA (analog), digital signal output
Ambient temperature automatic compensation function
/AUTOMATIC COMPENSATION

/PARAMETER SETTINGS
Zero/quantity conversion, fault alarm, unit conversion, fine adjustment, etc.

/DIGITAL COMMUNICATION
HART communication various commands 5
/APPEARANCE
CSA,FM,ATEX,GOST6
/FEATURE
High accuracy: ±0.075% of span(±0.04% of span)
Stability: ±0.01%/year
High turndown ratio: 100:1
/FLEXIBILITY
Parameter setting via HART ® protocol commands
Zero point adjustment (Zero point adjustment) 8
/RELIABILITY
Mean time between failures of 20 years; continuous self-detection function (sensor, memory, communication); automatic compensation function (ambient temperature compensation, sensor input linearization); software and hardware fault alarm function; configuration protection: EEPROM write protection function; CE EMC standards (EN50081-2, EN50082-2)

 

Packing & Delivery
Insertion type thermal gas mass flow meter RS-485,Modbus,RTU 1

FAQ
1. Q: What information need to be provided to choose the suitable model?
A: Application field, Nominal pressure ,Medium & medium temperture , Power supply , Output,
Flow range, Accuracy, Connection and other parameters.
2. Q: Are you a trade company or a manufacturer?
A: We are an ISO approved manufacturer specialized in level and flow measuring instruments.
OEM & ODM service are available. Welcome to visit us in China.
3. Q: What is your MOQ?
A: To start our cooperation, sample order is acceptable.
4. Q: What is your delivery date for the Intelligent Mini Micro Turbine Fuel Oil Diesel Flow Meter?
A: The delivery date is about 3-15 working days after receipt of payment.
5. Q: What is your payment terms?
A: We support T/T, PayPal ,Western Union.
For mass production order, it is 30% deposit in advance and 70% balance before shipment.
6. Q: Do you have a warranty for the Flow Meter?
A: Yes, we have the warranty of 12 months.

Contact Us at Any Time

86-400-839-1983
No. 66, Changwang Road, Dongqiao Town, Xiangcheng District, Suzhou City, Jiangsu Province
Send your inquiry directly to us